Shopping Cart
now in your cart
0 items
Search
Phone (602) 841-9283
Toll Free: 888-875-WAVE
Free Shipping! (Orders over $129)
Home
Ventilation Fans Clearance
New Products
Specials
All Products
Reviews
Contact Us
FAQ
Featured
About Us
Home
|
Log In
Manufacturers
Please Select
Air King Fans - CLEARANCE
Artisan Sinks and Drains
Arwa Faucets
Bates and Bates Sinks
Broan Ventilation Fans CLEARANCE
Edgar Berebi Hardware
Elite Bath Bronze Sinks
Enviro Bath
Fantech Exhaust Fans
Faucet Outlet
Flitz Polishing Products
Geberit Bath Tub Drains
Gel-Gloss - TR Industries
Gemini Bar Sinks
Gemini Bath & Kitchen Products
Gemini Faucets
Great Grates
Herbeau Creations
Houzer Sinks
Huntington Brass Faucets
JSG Oceana Glass Sinks
Lambro Venting Accessories
LaToscana by Paini
Linkasink Drains
Linkasink Sinks
Mico Designs LTD Faucets
Native Trails Copper Sinks
NuTone Exhaust Fans - CLEARANCE
Panasonic Exhaust Fans
Panasonic Fan Info
Polaris Sinks
Premier Copper Products
S & P - Soler & Palau Vent Fans
Schaub & Company Hardware
Schock Houzer Granite Sinks
Schön Plumbing
Shurtape
Sink Niche Copper Sinks
Solera Sinks & Faucets
Thompson Traders
Vents Ventilation Fans
Waste King - Disposals
Waste King Accessories
Waste King Commercial
Waste King Disposers
Wave Plumbing
WestBrass
What Odor?
Manufacturer Info
Panasonic Fan Info Homepage
Other products
Categories
Clearance Ventilation Fans
Ventilation Fans
>
Panasonic Bathroom Fans
>
Panasonic Fans - WhisperCeiling & WhisperLite
Panasonic Fans - WhisperFit, WhisperFit-Lite & WhisperWelcome
Panasonic Fans - Whisper Value & WhisperValue-Lite
Panasonic Fans - WhisperGreen & WhisperGreen-Lite
Panasonic Fans - WhisperSense & WhisperSense-Lite
Panasonic Fans - Whisper Warm - WhisperWall - WhisperLine
Panasonic Fans - WhisperRecessed Bathroom Fans
Panasonic Fans - Accessories
Discontinued Panasonic Models
Panasonic Fans Info
Panasonic Bathroom Fans - Site Map
Fantech Exhaust Fans >
S&P Soler & Palau Ventilation Fans >
Ventilation Fan Controls & Switches
Lambro Industries - Ducts & Accessories >
Ventilation & Exhaust Fans OUTLET
Vents - Ventilation Fans >
Waste King >
Whole House Ventilation >
Kitchen Sinks >
Bar & Prep Sinks >
Bathroom Sinks >
Bathroom Faucets >
Kitchen & Bar Faucets >
Decorative Hardware >
KITCHEN & BAR Products >
BATHROOM Products >
Copper Sinks - All Brands >
Range Hoods & Ventilation >
Cleaning Products >
Clearance Sale >
Shop by Brand >
Featured
Linkasink C020 Farmhouse Kitchen Copper Sink - CO20
$3,500.00
Sale: $2,100.00
Information
Shipping & Returns
Privacy Notice
Conditions of Use
Contact Us
Site Map
Gift Certificate FAQ
Discount Coupons
Newsletter Unsubscribe
Manufacturer Information
Customer Testimonials
Manufacturers Info
Panasonic Bathroom Fans
Ventilation Fans Clearance
Waste King Product Information
Fantech Ventilation Fans
Plumbing Glossary
Home
::
Ventilation Fans
::
Panasonic Bathroom Fans
::
Panasonic Fans Info
:: Panasonic Bathroom Fan Info: Sizing a Pansonic Bathroom Exhaust Fan
Panasonic Bathroom Fan Info: Sizing a Pansonic Bathroom Exhaust Fan
Panasonic Fans Info
larger image
Add to Cart:
Product Description
Details
Customers Also Purchased
Reviews
Product Description
Panasonic Bathroom Fan Info: Sizing a Pansonic Bathroom Exhaust Fan
Determine
the Application
Calculate the Area
Being Ventilated
Measure the Equivalent Duct Length (EDL)
Properly sized ventilation in airtight homes and apartments helps to assure healthy indoor air quality. Both intermittent (spot) ventilation and continuous (whole house) ventilation should be considered. Intermittent ventilation is used to exhaust sources of moisture and odors, while continuous ventilation is used to remove accumulated indoor air pollutants. Ventilating fans should be located near the source of moisture and indoor air pollutants in bathrooms, laundry rooms, kitchens, hobby rooms and smoking rooms.
Determine the Application
The first step when sizing for a ventilating fan is to determine the application. Decide whether you are sizing for intermittent or continuous ventilation. If intermittent, determine which application i.e. bathroom, kitchen or other. Use the following industry recommendations to determine Air Changes per Hour (ACH) for your specific application.
Intermittent (Spot) Ventilation:
The Home Ventilating Institute (HVI)
recommends the following Air Changes per Hour (ACH).
I. Bathrooms - 8 ACH
II. Kitchens - 15 ACH
III. Other Rooms - 6 ACH
Continuous (Whole House) Ventilation:
Many building codes have adopted the American Society of Heating Refrigerating and Air Conditioning Engineers (ASHRAE) Standard 62, as shown below.
I. House or apartment - 0.35 ACH
Properly sized ventilation in airtight homes and apartments helps to assure healthy indoor air quality. Both intermittent (spot) ventilation and continuous (whole house) ventilation should be considered. Intermittent ventilation is used to exhaust sources of moisture and odors, while continuous ventilation is used to remove accumulated indoor air pollutants. Ventilating fans should be located near the source of moisture and indoor air pollutants in bathrooms, laundry rooms, kitchens, hobby rooms and smoking rooms.
Determine the Application
The first step when sizing for a ventilating fan is to determine the application. Decide whether you are sizing for intermittent or continuous ventilation. If intermittent, determine which application i.e. bathroom, kitchen or other. Use the following industry recommendations to determine Air Changes per Hour (ACH) for your specific application.
Intermittent (Spot) Ventilation:
The Home Ventilating Institute (HVI)
recommends the following Air Changes per Hour (ACH).
I. Bathrooms - 8 ACH
II. Kitchens - 15 ACH
III. Other Rooms - 6 ACH
Continuous (Whole House) Ventilation:
Many building codes have adopted the American Society of Heating Refrigerating and Air Conditioning Engineers (ASHRAE) Standard 62, as shown below.
I. House or apartment - 0.35 ACH
Calculate the Area Being Ventilated
The second step is to calculate the area being ventilated. Calculate square feet or cubic feet depending on which sizing method you choose.
Both methods, the Sizing Chart Method and the Performance Curve Method, follow industry standards and will give you similar outcomes. The Sizing Chart Method is easier. The Performance Curve Method is often preferred by engineers.
Note:
You should check with your local building inspector to confirm that these methods are accepted in your area.
Sizing Chart Method
Performance Curve Method
Sizing Chart Method:
Example:
Sizing for an 8 ft x 12 ft x 8 ft ceiling bathroom using 12-foot long, 4 inch diameter aluminum flex duct, one elbow, one wall cap.
Step 1:
Determine the ACH required for the given application using the HVI and ASHRAE standards above.
•
Bathroom - 8 ACH
Step 2:
Calculate the Area to be ventilated in Square Feet.
2a.
•
2b.
Assuming 8 foot ceiling: room length x width.
8 ft x 12 ft = 96 sq ft.
Guideline for cathedral ceilings:
i.
ii.
10 - 12 ft cathedral = length x width x 1.25
12 - 16 ft cathedral = length x width x 1.5
Step 3:
Use the Equivalent Duct Length chart above to calculate the duct run.
3a.
3b.
3c.
•
12 ft flex aluminum duct x 1.25 = 15 feet EDL
One elbow equals 15 feet EDL
One roof jack equals 30 feet EDL
(12 ft length x 1.25 alum. flex) + 15 ft elbow + 30 ft wall cap = 60 ft EDL This is the equivalent duct length (or resistance) the fan must overcome to move air through the duct to the outside.
Step 4:
See the Fan Sizing Charts
for the appropriate Panasonic model.
4a.
4b.
•
Select the correct ACH chart for the application
Find the intersect of the Square Feet and EDL to determine the appropriate Panasonic model(s). When values are not exact move to next higher value.
100 sq ft by 60 ft EDL = FV-15VQ3
Performance Curve Method:
A ventilating fan's performance is plotted on a graph called a performance curve. The performance curve shows airflow in cubic feet per minute (CFM) along the horizontal axis and static pressure (resistance) along the vertical axis. Figure A shows how a performance curve works. The fan with a "Closed duct" has high static pressure and no airflow; and the fan with "No duct" has low static pressure and high airflow. In reality, an installed fan will be somewhere in between these two points.
This method requires two calculations and plotting on a graph. First is the Airflow (CFM) calculation, which calculates cubic feet and the required CFM for the area to be ventilated. The second is the Static Pressure (Resistance) calculation, which calculates the Equivalent Duct Length (EDL) of a straight duct run from the inlet to the termination (outside) point of the building. Third, the result of airflow and static pressure calculations are then plotted on the performance curve of ventilating fan models to find the ideal model for a given application and duct run.
Example:
Sizing for an 8 ft x 12 ft x 8 ft ceiling bathroom using 12-foot long, 4 inch diameter aluminum flex duct, one elbow, one wall cap.
Step 1:
Airflow (CFM) Calculation:
First calculate area in cubic feet (length x width x ceiling height). Then divide this number by 60 to get the Cubic Feet per Minute (CFM) required to replenish the entire air volume in one hour. Next, multiply the CFM value by the appropriate ACH value for the given application.
1a.
1b.
1c.
•
8 ft x 12 ft x 8 ft = 768 cubic feet
768/60 = 12.8 CFM value
12.8 x 8 ACH
102 CFM for intermittent bathroom ventilation
Step 2:
Static Pressure (Resistance) Calculation:
The Static Pressure calculation provides EDL and adjusts for airflow resistance caused by duct material, elbows, and terminations devices.
2a.
2b.
2c.
•
12 ft flex aluminum duct x 1.25 = 15 feet EDL
One elbow equals 15 feet EDL
One roof jack equals 30 feet EDL
15 + 15 + 30 = 60 feet total EDL.
This is the equivalent duct length (or resistance) the fan must overcome to move air through the duct to the outside.
Step 3:
Airflow and Static Pressure on a Performance Curve Chart:
The next step is to identify a fan that will provide 102 CFM at 60 EDL. Figure B shows the performance curve for a Panasonic model FV-15VQ3. First, find 60 EDL and then drop straight down to the horizontal axis to determine the CFM's delivered at 60 EDL.
Example:
3a.
3b.
•
Locate the point on the blue "FAN" curve at 60 ft. In this case, it is a point on the blue fan curve between the yellow "50 ft" and blue "75 ft" lines.
From this point on the FAN line move straight down to the horizontal axis to read CFM. In this case, it is close to 100 CFM.
Therefore, a Panasonic FV-15VQ3 is the appropriate model
Repeat Step 3.
You may need to repeat Step 3 on the performance curve different fan models until you find a model that matches the desired CFM with EDL.
To see Performance Curves per model
click here
.
Determine the Application
The first step when sizing for a ventilating fan is to determine the application. Decide whether you are sizing for intermittent or continuous ventilation. If intermittent, determine which application i.e. bathroom, kitchen or other. Use the following industry recommendations to determine Air Changes per Hour (ACH) for your specific application.
Intermittent (Spot) Ventilation:
The Home Ventilating Institute (HVI)
recommends the following Air Changes per Hour (ACH).
I. Bathrooms - 8 ACH
II. Kitchens - 15 ACH
III. Other Rooms - 6 ACH
Continuous (Whole House) Ventilation:
Many building codes have adopted the American Society of Heating Refrigerating and Air Conditioning Engineers (ASHRAE) Standard 62, as shown below.
I. House or apartment - 0.35 ACH
Calculate the Area Being Ventilated
The second step is to calculate the area being ventilated. Calculate square feet or cubic feet depending on which sizing method you choose.
Both methods, the Sizing Chart Method and the Performance Curve Method, follow industry standards and will give you similar outcomes. The Sizing Chart Method is easier. The Performance Curve Method is often preferred by engineers.
Note:
You should check with your local building inspector to confirm that these methods are accepted in your area.
Sizing Chart Method
Performance Curve Method
Sizing Chart Method:
Example:
Sizing for an 8 ft x 12 ft x 8 ft ceiling bathroom using 12-foot long, 4 inch diameter aluminum flex duct, one elbow, one wall cap.
Step 1:
Determine the ACH required for the given application using the HVI and ASHRAE standards above.
•
Bathroom - 8 ACH
Step 2:
Calculate the Area to be ventilated in Square Feet.
2a.
•
2b.
Assuming 8 foot ceiling: room length x width.
8 ft x 12 ft = 96 sq ft.
Guideline for cathedral ceilings:
i.
ii.
10 - 12 ft cathedral = length x width x 1.25
12 - 16 ft cathedral = length x width x 1.5
Step 3:
Use the Equivalent Duct Length chart above to calculate the duct run.
3a.
3b.
3c.
•
12 ft flex aluminum duct x 1.25 = 15 feet EDL
One elbow equals 15 feet EDL
One roof jack equals 30 feet EDL
(12 ft length x 1.25 alum. flex) + 15 ft elbow + 30 ft wall cap = 60 ft EDL This is the equivalent duct length (or resistance) the fan must overcome to move air through the duct to the outside.
Step 4:
See the Fan Sizing Charts
for the appropriate Panasonic model.
4a.
4b.
•
Select the correct ACH chart for the application
Find the intersect of the Square Feet and EDL to determine the appropriate Panasonic model(s). When values are not exact move to next higher value.
100 sq ft by 60 ft EDL = FV-15VQ3
Performance Curve Method:
A ventilating fan's performance is plotted on a graph called a performance curve. The performance curve shows airflow in cubic feet per minute (CFM) along the horizontal axis and static pressure (resistance) along the vertical axis. Figure A shows how a performance curve works. The fan with a "Closed duct" has high static pressure and no airflow; and the fan with "No duct" has low static pressure and high airflow. In reality, an installed fan will be somewhere in between these two points.
This method requires two calculations and plotting on a graph. First is the Airflow (CFM) calculation, which calculates cubic feet and the required CFM for the area to be ventilated. The second is the Static Pressure (Resistance) calculation, which calculates the Equivalent Duct Length (EDL) of a straight duct run from the inlet to the termination (outside) point of the building. Third, the result of airflow and static pressure calculations are then plotted on the performance curve of ventilating fan models to find the ideal model for a given application and duct run.
Example:
Sizing for an 8 ft x 12 ft x 8 ft ceiling bathroom using 12-foot long, 4 inch diameter aluminum flex duct, one elbow, one wall cap.
Step 1:
Airflow (CFM) Calculation:
First calculate area in cubic feet (length x width x ceiling height). Then divide this number by 60 to get the Cubic Feet per Minute (CFM) required to replenish the entire air volume in one hour. Next, multiply the CFM value by the appropriate ACH value for the given application.
1a.
1b.
1c.
•
8 ft x 12 ft x 8 ft = 768 cubic feet
768/60 = 12.8 CFM value
12.8 x 8 ACH
102 CFM for intermittent bathroom ventilation
Step 2:
Static Pressure (Resistance) Calculation:
The Static Pressure calculation provides EDL and adjusts for airflow resistance caused by duct material, elbows, and terminations devices.
2a.
2b.
2c.
•
12 ft flex aluminum duct x 1.25 = 15 feet EDL
One elbow equals 15 feet EDL
One roof jack equals 30 feet EDL
15 + 15 + 30 = 60 feet total EDL.
This is the equivalent duct length (or resistance) the fan must overcome to move air through the duct to the outside.
Step 3:
Airflow and Static Pressure on a Performance Curve Chart:
The next step is to identify a fan that will provide 102 CFM at 60 EDL. Figure B shows the performance curve for a Panasonic model FV-15VQ3. First, find 60 EDL and then drop straight down to the horizontal axis to determine the CFM's delivered at 60 EDL.
Example:
3a.
3b.
•
Locate the point on the blue "FAN" curve at 60 ft. In this case, it is a point on the blue fan curve between the yellow "50 ft" and blue "75 ft" lines.
From this point on the FAN line move straight down to the horizontal axis to read CFM. In this case, it is close to 100 CFM.
Therefore, a Panasonic FV-15VQ3 is the appropriate model
Repeat Step 3.
You may need to repeat Step 3 on the performance curve different fan models until you find a model that matches the desired CFM with EDL.
To see Performance Curves per model
click here
.
Properly sized ventilation in airtight homes and apartments helps to assure healthy indoor air quality. Both intermittent (spot) ventilation and continuous (whole house) ventilation should be considered. Intermittent ventilation is used to exhaust sources of moisture and odors, while continuous ventilation is used to remove accumulated indoor air pollutants. Ventilating fans should be located near the source of moisture and indoor air pollutants in bathrooms, laundry rooms, kitchens, hobby rooms and smoking rooms.
Measure the Equivalent Duct Length (EDL)
The third step is to measure the Equivalent Duct Length of the planned duct run. This requires a basic understanding of static pressure caused by a duct run design and its components.
Static Pressure and Duct Run:
A ventilating fan must overcome resistance when pushing air from the inlet, through the duct, to the outside of the building. This resistance is known as static pressure. The amount of static pressure depends on the duct length, type of duct, elbows and the roof jack or wall cap.
Equivalent Duct Length (EDL):
Static pressure in a typical duct run is caused by the type of duct material, elbows, exterior wall cap, etc. The table below shows the standard values for duct components. The EDL chart allows you to calculate the equivalent straight duct length in order to overcome static pressure caused by each component in a duct run. The EDL helps assure the fan performs as expected under the airflow resistance caused by the components listed in this chart.
Details
Model: Sizing an Exhaust Fan
Manufactured by: Panasonic Fan Info
Customers who bought this product also purchased...
Panasonic Fans - WhisperGreen Lite FV-08VKSL3 Bathroom Fan w Light 80 cfm less than 0.3 Sones 4" Duct
Panasonic Fans - FV-20VQ3 WhisperCeiling Bathroom Exhaust Fan - 190 cfm - 1.3 Sones - 6 Inch Duct
X Panasonic Fans - FV-08VQL4 (FV-08VQL5) WhisperLite Bathroom Exhaust Fan - 80 cfm - 0.3 Sones - 4 Inch Duct
Reviews
Panasonic Bathroom Fan Info: Sizing a Pansonic Bathroom Exhaust Fan
[Sizing an Exhaust Fan]
Sizing an Exhaust Fan
larger image
There are currently no product reviews.
NOTE:
Reviews may require prior approval before they will be displayed
Panasonic Bathroom Fan Info: Sizing a Pansonic Bathroom Exhaust Fan
Determine
the Application
Calculate the Area
Being Ventilated
Measure the Equivalent Duct Length (EDL)
Properly sized ventilation in airtight homes and apartments helps to assure healthy indoor air quality. Both intermittent (spot) ventilation and continuous (whole house) ventilation should be considered. Intermittent ventilation is used to exhaust sources of moisture and odors, while continuous ventilation is used to remove accumulated indoor air pollutants. Ventilating fans should be located near the source of moisture and indoor air pollutants in bathrooms, laundry rooms, kitchens, hobby rooms and smoking rooms.
Determine the Application
The first step when sizing for a ventilating fan is to determine the application. Decide whether you are sizing for intermittent or continuous ventilation. If intermittent, determine which application i.e. bathroom, kitchen or other. Use the following industry recommendations to determine Air Changes per Hour (ACH) for your specific application.
Intermittent (Spot) Ventilation:
The Home Ventilating Institute (HVI)
recommends the following Air Changes per Hour (ACH).
I. Bathrooms - 8 ACH
II. Kitchens - 15 ACH
III. Other Rooms - 6 ACH
Continuous (Whole House) Ventilation:
Many building codes have adopted the American Society of Heating Refrigerating and Air Conditioning Engineers (ASHRAE) Standard 62, as shown below.
I. House or apartment - 0.35 ACH
Properly sized ventilation in airtight homes and apartments helps to assure healthy indoor air quality. Both intermittent (spot) ventilation and continuous (whole house) ventilation should be considered. Intermittent ventilation is used to exhaust sources of moisture and odors, while continuous ventilation is used to remove accumulated indoor air pollutants. Ventilating fans should be located near the source of moisture and indoor air pollutants in bathrooms, laundry rooms, kitchens, hobby rooms and smoking rooms.
Determine the Application
The first step when sizing for a ventilating fan is to determine the application. Decide whether you are sizing for intermittent or continuous ventilation. If intermittent, determine which application i.e. bathroom, kitchen or other. Use the following industry recommendations to determine Air Changes per Hour (ACH) for your specific application.
Intermittent (Spot) Ventilation:
The Home Ventilating Institute (HVI)
recommends the following Air Changes per Hour (ACH).
I. Bathrooms - 8 ACH
II. Kitchens - 15 ACH
III. Other Rooms - 6 ACH
Continuous (Whole House) Ventilation:
Many building codes have adopted the American Society of Heating Refrigerating and Air Conditioning Engineers (ASHRAE) Standard 62, as shown below.
I. House or apartment - 0.35 ACH
Calculate the Area Being Ventilated
The second step is to calculate the area being ventilated. Calculate square feet or cubic feet depending on which sizing method you choose.
Both methods, the Sizing Chart Method and the Performance Curve Method, follow industry standards and will give you similar outcomes. The Sizing Chart Method is easier. The Performance Curve Method is often preferred by engineers.
Note:
You should check with your local building inspector to confirm that these methods are accepted in your area.
Sizing Chart Method
Performance Curve Method
Sizing Chart Method:
Example:
Sizing for an 8 ft x 12 ft x 8 ft ceiling bathroom using 12-foot long, 4 inch diameter aluminum flex duct, one elbow, one wall cap.
Step 1:
Determine the ACH required for the given application using the HVI and ASHRAE standards above.
•
Bathroom - 8 ACH
Step 2:
Calculate the Area to be ventilated in Square Feet.
2a.
•
2b.
Assuming 8 foot ceiling: room length x width.
8 ft x 12 ft = 96 sq ft.
Guideline for cathedral ceilings:
i.
ii.
10 - 12 ft cathedral = length x width x 1.25
12 - 16 ft cathedral = length x width x 1.5
Step 3:
Use the Equivalent Duct Length chart above to calculate the duct run.
3a.
3b.
3c.
•
12 ft flex aluminum duct x 1.25 = 15 feet EDL
One elbow equals 15 feet EDL
One roof jack equals 30 feet EDL
(12 ft length x 1.25 alum. flex) + 15 ft elbow + 30 ft wall cap = 60 ft EDL This is the equivalent duct length (or resistance) the fan must overcome to move air through the duct to the outside.
Step 4:
See the Fan Sizing Charts
for the appropriate Panasonic model.
4a.
4b.
•
Select the correct ACH chart for the application
Find the intersect of the Square Feet and EDL to determine the appropriate Panasonic model(s). When values are not exact move to next higher value.
100 sq ft by 60 ft EDL = FV-15VQ3
Performance Curve Method:
A ventilating fan's performance is plotted on a graph called a performance curve. The performance curve shows airflow in cubic feet per minute (CFM) along the horizontal axis and static pressure (resistance) along the vertical axis. Figure A shows how a performance curve works. The fan with a "Closed duct" has high static pressure and no airflow; and the fan with "No duct" has low static pressure and high airflow. In reality, an installed fan will be somewhere in between these two points.
This method requires two calculations and plotting on a graph. First is the Airflow (CFM) calculation, which calculates cubic feet and the required CFM for the area to be ventilated. The second is the Static Pressure (Resistance) calculation, which calculates the Equivalent Duct Length (EDL) of a straight duct run from the inlet to the termination (outside) point of the building. Third, the result of airflow and static pressure calculations are then plotted on the performance curve of ventilating fan models to find the ideal model for a given application and duct run.
Example:
Sizing for an 8 ft x 12 ft x 8 ft ceiling bathroom using 12-foot long, 4 inch diameter aluminum flex duct, one elbow, one wall cap.
Step 1:
Airflow (CFM) Calculation:
First calculate area in cubic feet (length x width x ceiling height). Then divide this number by 60 to get the Cubic Feet per Minute (CFM) required to replenish the entire air volume in one hour. Next, multiply the CFM value by the appropriate ACH value for the given application.
1a.
1b.
1c.
•
8 ft x 12 ft x 8 ft = 768 cubic feet
768/60 = 12.8 CFM value
12.8 x 8 ACH
102 CFM for intermittent bathroom ventilation
Step 2:
Static Pressure (Resistance) Calculation:
The Static Pressure calculation provides EDL and adjusts for airflow resistance caused by duct material, elbows, and terminations devices.
2a.
2b.
2c.
•
12 ft flex aluminum duct x 1.25 = 15 feet EDL
One elbow equals 15 feet EDL
One roof jack equals 30 feet EDL
15 + 15 + 30 = 60 feet total EDL.
This is the equivalent duct length (or resistance) the fan must overcome to move air through the duct to the outside.
Step 3:
Airflow and Static Pressure on a Performance Curve Chart:
The next step is to identify a fan that will provide 102 CFM at 60 EDL. Figure B shows the performance curve for a Panasonic model FV-15VQ3. First, find 60 EDL and then drop straight down to the horizontal axis to determine the CFM's delivered at 60 EDL.
Example:
3a.
3b.
•
Locate the point on the blue "FAN" curve at 60 ft. In this case, it is a point on the blue fan curve between the yellow "50 ft" and blue "75 ft" lines.
From this point on the FAN line move straight down to the horizontal axis to read CFM. In this case, it is close to 100 CFM.
Therefore, a Panasonic FV-15VQ3 is the appropriate model
Repeat Step 3.
You may need to repeat Step 3 on the performance curve different fan models until you find a model that matches the desired CFM with EDL.
To see Performance Curves per model
click here
.
Determine the Application
The first step when sizing for a ventilating fan is to determine the application. Decide whether you are sizing for intermittent or continuous ventilation. If intermittent, determine which application i.e. bathroom, kitchen or other. Use the following industry recommendations to determine Air Changes per Hour (ACH) for your specific application.
Intermittent (Spot) Ventilation:
The Home Ventilating Institute (HVI)
recommends the following Air Changes per Hour (ACH).
I. Bathrooms - 8 ACH
II. Kitchens - 15 ACH
III. Other Rooms - 6 ACH
Continuous (Whole House) Ventilation:
Many building codes have adopted the American Society of Heating Refrigerating and Air Conditioning Engineers (ASHRAE) Standard 62, as shown below.
I. House or apartment - 0.35 ACH
Calculate the Area Being Ventilated
The second step is to calculate the area being ventilated. Calculate square feet or cubic feet depending on which sizing method you choose.
Both methods, the Sizing Chart Method and the Performance Curve Method, follow industry standards and will give you similar outcomes. The Sizing Chart Method is easier. The Performance Curve Method is often preferred by engineers.
Note:
You should check with your local building inspector to confirm that these methods are accepted in your area.
Sizing Chart Method
Performance Curve Method
Sizing Chart Method:
Example:
Sizing for an 8 ft x 12 ft x 8 ft ceiling bathroom using 12-foot long, 4 inch diameter aluminum flex duct, one elbow, one wall cap.
Step 1:
Determine the ACH required for the given application using the HVI and ASHRAE standards above.
•
Bathroom - 8 ACH
Step 2:
Calculate the Area to be ventilated in Square Feet.
2a.
•
2b.
Assuming 8 foot ceiling: room length x width.
8 ft x 12 ft = 96 sq ft.
Guideline for cathedral ceilings:
i.
ii.
10 - 12 ft cathedral = length x width x 1.25
12 - 16 ft cathedral = length x width x 1.5
Step 3:
Use the Equivalent Duct Length chart above to calculate the duct run.
3a.
3b.
3c.
•
12 ft flex aluminum duct x 1.25 = 15 feet EDL
One elbow equals 15 feet EDL
One roof jack equals 30 feet EDL
(12 ft length x 1.25 alum. flex) + 15 ft elbow + 30 ft wall cap = 60 ft EDL This is the equivalent duct length (or resistance) the fan must overcome to move air through the duct to the outside.
Step 4:
See the Fan Sizing Charts
for the appropriate Panasonic model.
4a.
4b.
•
Select the correct ACH chart for the application
Find the intersect of the Square Feet and EDL to determine the appropriate Panasonic model(s). When values are not exact move to next higher value.
100 sq ft by 60 ft EDL = FV-15VQ3
Performance Curve Method:
A ventilating fan's performance is plotted on a graph called a performance curve. The performance curve shows airflow in cubic feet per minute (CFM) along the horizontal axis and static pressure (resistance) along the vertical axis. Figure A shows how a performance curve works. The fan with a "Closed duct" has high static pressure and no airflow; and the fan with "No duct" has low static pressure and high airflow. In reality, an installed fan will be somewhere in between these two points.
This method requires two calculations and plotting on a graph. First is the Airflow (CFM) calculation, which calculates cubic feet and the required CFM for the area to be ventilated. The second is the Static Pressure (Resistance) calculation, which calculates the Equivalent Duct Length (EDL) of a straight duct run from the inlet to the termination (outside) point of the building. Third, the result of airflow and static pressure calculations are then plotted on the performance curve of ventilating fan models to find the ideal model for a given application and duct run.
Example:
Sizing for an 8 ft x 12 ft x 8 ft ceiling bathroom using 12-foot long, 4 inch diameter aluminum flex duct, one elbow, one wall cap.
Step 1:
Airflow (CFM) Calculation:
First calculate area in cubic feet (length x width x ceiling height). Then divide this number by 60 to get the Cubic Feet per Minute (CFM) required to replenish the entire air volume in one hour. Next, multiply the CFM value by the appropriate ACH value for the given application.
1a.
1b.
1c.
•
8 ft x 12 ft x 8 ft = 768 cubic feet
768/60 = 12.8 CFM value
12.8 x 8 ACH
102 CFM for intermittent bathroom ventilation
Step 2:
Static Pressure (Resistance) Calculation:
The Static Pressure calculation provides EDL and adjusts for airflow resistance caused by duct material, elbows, and terminations devices.
2a.
2b.
2c.
•
12 ft flex aluminum duct x 1.25 = 15 feet EDL
One elbow equals 15 feet EDL
One roof jack equals 30 feet EDL
15 + 15 + 30 = 60 feet total EDL.
This is the equivalent duct length (or resistance) the fan must overcome to move air through the duct to the outside.
Step 3:
Airflow and Static Pressure on a Performance Curve Chart:
The next step is to identify a fan that will provide 102 CFM at 60 EDL. Figure B shows the performance curve for a Panasonic model FV-15VQ3. First, find 60 EDL and then drop straight down to the horizontal axis to determine the CFM's delivered at 60 EDL.
Example:
3a.
3b.
•
Locate the point on the blue "FAN" curve at 60 ft. In this case, it is a point on the blue fan curve between the yellow "50 ft" and blue "75 ft" lines.
From this point on the FAN line move straight down to the horizontal axis to read CFM. In this case, it is close to 100 CFM.
Therefore, a Panasonic FV-15VQ3 is the appropriate model
Repeat Step 3.
You may need to repeat Step 3 on the performance curve different fan models until you find a model that matches the desired CFM with EDL.
To see Performance Curves per model
click here
.
Properly sized ventilation in airtight homes and apartments helps to assure healthy indoor air quality. Both intermittent (spot) ventilation and continuous (whole house) ventilation should be considered. Intermittent ventilation is used to exhaust sources of moisture and odors, while continuous ventilation is used to remove accumulated indoor air pollutants. Ventilating fans should be located near the source of moisture and indoor air pollutants in bathrooms, laundry rooms, kitchens, hobby rooms and smoking rooms.
Measure the Equivalent Duct Length (EDL)
The third step is to measure the Equivalent Duct Length of the planned duct run. This requires a basic understanding of static pressure caused by a duct run design and its components.
Static Pressure and Duct Run:
A ventilating fan must overcome resistance when pushing air from the inlet, through the duct, to the outside of the building. This resistance is known as static pressure. The amount of static pressure depends on the duct length, type of duct, elbows and the roof jack or wall cap.
Equivalent Duct Length (EDL):
Static pressure in a typical duct run is caused by the type of duct material, elbows, exterior wall cap, etc. The table below shows the standard values for duct components. The EDL chart allows you to calculate the equivalent straight duct length in order to overcome static pressure caused by each component in a duct run. The EDL helps assure the fan performs as expected under the airflow resistance caused by the components listed in this chart.
Model: Sizing an Exhaust Fan
Manufactured by: Panasonic Fan Info
Product 2/10
Customers who bought this product also purchased...
Panasonic Fans - WhisperGreen Lite FV-08VKSL3 Bathroom Fan w Light 80 cfm less than 0.3 Sones 4" Duct
Panasonic Fans - FV-20VQ3 WhisperCeiling Bathroom Exhaust Fan - 190 cfm - 1.3 Sones - 6 Inch Duct
X Panasonic Fans - FV-08VQL4 (FV-08VQL5) WhisperLite Bathroom Exhaust Fan - 80 cfm - 0.3 Sones - 4 Inch Duct